Old A/C unit failing, getting a new one.
Jeff - Wylie, TX
Jacob came out on time and it’s time to replace HVAC. They are going to replace it all tomorrow.
Very thorough, Great service !
Jeff - Wylie, TX
Jacob arrived on time and was very thorough with his inspection of our A/C unit. He explained everything about what he did and found.
System Evaluation
Satisfied - Wylie, TX
My system quit cooling and outside unit wouldn't come on and was tripping the breakers. I contacted Air Force One was given a window of availability and Kevin came out at the start of that time window fast service, he checked out my system diagnosed the problem and provided options for replacing parts or the system. System replacement made more sense than throwing good money at an old system. New system cost wasn't that much more than replacing the outside unit that uses the old freon who know's how long that will remain available. I chose to go with a new system that's more efficient rather than limp along the old one. I hope to see electric bills go down with the new system too.
Excellent Service
John - Wylie, TX
Had Wilson come out and check my system and they wanted $4k to replace the outside unit. I wanted a second opinion and Air Force One has fixed the problem for $120... They actually troubleshoot instead of trying to sell me a new unit. I have a new AC company.
Outstanding
ken - Wylie, TX
I have had the maintenance agreement for now the 4th year, and going on nine years for the equipment, and Air Force One has been exception from day one (Install, maintenance, issues). Kevin did a great job, appreciated.

Jacob L.
Summertime HVAC Installation performed for a residential client near Ranchwood Drive. Installed 4 Ton 16 SEER Lennox Heat Pump Single Stage System and tested for performance.

Jacob L.
1850 4 Ton 16 SEER Single Stage Lennox Heat Pump System Installation

Jacob L.
Springtime HVAC Repair Service for a residential customer near Southfork Blvd. Found multiple issues with the system, mainly compressor windings burned out. Recommend replacement.

Jacob L.
Springtime HVAC Maintenance for a residential customer near Muddy Creek. Inspected for cooling found both systems low on r22 refrigerant. Due to cost repair is not a feasible option at this time. Sealed leaking float switch.

Tara R.
HVAC Repair for a residential customer. Disconnect was removed when technician arrived. No legible data plate on heat pump. System is r22 delta T is 12. Pressures indicate system is low on refrigerant.

SAMUEL H.
Upon arrival found system to be off as well as low on refrigerant advise the customer about repairs she will relay to landlord

Tara R.
Inspection of inside unit revealed no faults. Outside dual run capacitor was found to be below the recommended threshold and was recommended for replacement.

Tara R.
Inside air handler fan wheel heavily caked with debris. Blower motor capacitor below standard capacitance. Outside unit heavily corroded and refrigerant pressures lower than normal. Customer requested a quote on upgrading to a new unit.

josue_bazan56@hotmail.com
2 system spring PM. Units checked out good. No issues found at this time. Systems are ready for summer weather. Added customer supplied float switches to units. Units are operating normally.

SAMUEL H.
system had a leak customer wanted to use his own refrigerant added leak stop system is working normal at this time wound the customer about the potential faults that might happen when we recharge the system

Rick M.
Technician ricordo performed diagnosis on a addict gas heating furnace found d the main heating limit at 140 degrees was stuck open causing bored to never kick the heating on customer said he would purchase it in house Monday morning otherwise jumped around safety switch tested everything else could not find any other issues once part has been replaced system should be ready for the cold winter thank you for your business from your tech ricardo moreno and Air Force One

Kevin B.
Added compressor saver to trane condenser

Kevin B.
Found carrier heat pump with a compressor shorted to ground, give customer solutions on replacement

Rick M.
ac not cool Notes added by tech Rick on 8/8/2015 10:06:05 PM Had to water wash condenaing coil. Notes added by tech Rick on 8/8/2015 10:08:52 PM Need to double check if we ever did any of the club maintenence on both units. ???

Rick M.
ac not cool Notes added by tech Rick on 8/8/2015 10:06:05 PM Had to water wash condenaing coil. Notes added by tech Rick on 8/8/2015 10:08:52 PM Need to double check if we ever did any of the club maintenence on both units. ???

Rick M.
DIAGNOSTIC ANALYSIS - RESIDENTIAL 410a handler has been txv changed to r22. System overcharged by 3lbs r22. Recoverd it. Txv sensing bilb installed backwards &/or upsidedown. Now freon level running @ charging chart from manufacture. Found on the outside units door.

Rick M.
DIAGNOSTIC ANALYSIS - RESIDENTIAL 410a handler has been txv changed to r22. System overcharged by 3lbs r22. Recoverd it. Txv sensing bilb installed backwards &/or upsidedown. Now frwfreon on level running @ charging chart from manufacture.

Rick M.
DIAGNOSTIC ANALYSIS - RESIDENTIAL 410a handler has been txv changed to r22. System overcharged by 3lbs r22. Recoverd it. Txv sensing bilb installed backwards &/or upsidedown. Now frwfreon on level running @ charging chart from manufacture.

Kevin B.
Cooling Check of 2 rheem systems. Filters were clean, 20x25x1-2. Washed condenser coils, checked motors, capacitors and electrical. Declined blower motor capacitor. Checked r22 levels, normal. Both systems working properly.

Kevin B.
Checked wiring on condenser fan motor for a carrier unit

Rick M.
Technician Ricardo diagnostic found TRANE control board , hot surface ignitor , flame sensor & blower motor 15 MFD capacitor weak and not allowing heating to function . Replace all parts & 21X27X5 TRANE filter & tested heating and cooling . system heating now just fine Also would like information on bringing his return system up to par its restricted down to two tons of air on a 5 ton system

Rick M.
Amana gas horizontal left heating system in the attic had a defective hot surface ignitor replaced igniter tested heating working fine also found over amping and loud on startup blower motor customer declined for now on that repair otherwise system working now